Compare Products
Hide
VS
Model
Dòng
Tính năng nổi bật
Hardware Specifications |
RG-CS85-24GT8XS-D |
RG-CS85-24SFP/8GT8XS-D |
RG-CS85-48GT4XS-D |
RG-CS85-48GT4XS-HPD |
RG-CS85-48SFP4XS-D |
Interface Specifications |
|||||
Fixed ports |
24 x 10/100/1000 Mbps electrical ports with auto-negotiation, 8 x 1GE/10GE SFP+ ports |
24 x 1000 Mbps SFP ports (ports 1-16 are 100/1000 Mbps SFP ports), 8 x 10/100/1000 Mbps combo ports with auto-negotiation, 8 x 1GE/10GE SFP+ ports |
48 x 10/100/1000 Mbps electrical ports with auto-negotiation, 4 x 1GE/10GE SFP+ ports |
48 x 10/100/1000 Mbps electrical ports with auto-negotiation, 4 x 1GE/10GE SFP+ ports |
48 x 1000 Mbps SFP ports, 4 x 1GE/10GE SFP+ ports |
Fan modules |
3 |
3 |
3 |
2 |
3 |
Power modules |
2 |
2 |
2 |
2 |
2 |
Fixed management ports |
1 x console, 1 x MGMT, 1 x USB3.0 |
1 x console, 1 x MGMT, 1 x USB3.0 |
1 x console, 1 x MGMT, 1 x USB3.0 |
1 x console, 1 x MGMT, 1 x USB3.0 |
1 x console, 1 x MGMT, 1 x USB3.0 |
Expansion slot |
One expansion slot |
One expansion slot |
One expansion slot |
One expansion slot |
One expansion slot |
System Specifications |
|||||
Packet forwarding rate |
426Mpps/600Mpps |
406Mpps/600Mpps |
|||
System Switching capacity |
880Gbps |
||||
MAC address |
64000 |
64000 |
64000 |
64000 |
64000 |
ARP table |
24000 |
24000 |
24000 |
24000 |
24000 |
Routing table size (IPv4) |
24K |
24K |
24K |
24K |
24K |
Routing table size (IPv6) |
14K |
14K |
14K |
14K |
14K |
ACL entries |
In: 7000 Out:1500 |
||||
Number of VSU members |
4 |
4 |
4 |
4 |
4 |
Dimensions and Weight |
|
||||
Dimensions (W x D x H) |
440 mm x 340 mm x 44 mm |
440 mm x 340 mm x 44 mm |
440 mm x 340 mm x 44 mm |
442 mm x 420 mm x 43.6 mm |
442 mm x 420 mm x 43.6 mm |
Weight (empty chassis and fan modules) |
4.4 kg |
4.3 kg |
4.5 kg |
5.5 kg |
5.3 kg |
CPU and Storage |
|||||
CPU |
Dual-core CPU, 1.2 GHz |
Dual-core CPU, 1.2 GHz |
Dual-core CPU, 1.2 GHz |
Dual-core CPU, 1.2 GHz |
Dual-core CPU, 1.2 GHz |
Storage |
Flash memory: 4 GB SDRAM: 1 GB |
Flash memory: 4 GB SDRAM: 1 GB |
Flash memory: 4 GB SDRAM: 1 GB |
Flash memory: 4 GB SDRAM: 2 GB |
Flash memory: 4 GB SDRAM: 2 GB |
Power and Consumption |
|||||
Maximum power consumption |
< 60 W (excluding expansion modules) |
< 77 W (excluding expansion modules) |
< 70 W (excluding expansion modules) |
< 110 W (non-PoE) < 1590 W (PoE full load) |
< 150 W |
Maximum output power |
RG-PA150I-F: 150 W RG-PA150IB-F: 150 W |
RG-PA150I-F: 150 W RG-PA150IB-F: 150 W |
RG-PA150I-F: 150 W RG-PA150IB-F: 150 W |
RG-PA600I-P-F: 600 W RG-PA1000I-P-F: 176 V AC to 290 V AC, 1000 W 90 V AC to 176 V AC, 930 W (PoE: 740 W) |
RG-PA150IB-F: 150 W RG-PA150I-F: 150 W |
Rated input voltage |
AC: 100 V to 240 V
HVDC: 240 V
LVDC: 48 V to 60 V
|
AC: 100 V to 240 V
HVDC: 240 V
LVDC: 48 V to 60 V |
AC: 100 V to 240 V
HVDC: 240 V
LVDC: 48 V to 60 V |
AC: 200 V to 240 V
DC: 48 V to 60 V |
AC: 100 V to 240 V DC: 48 V to 60 V |
Maximum input voltage |
AC: 90 V to 264 V
HVDC: 192 V to 288 V
LVDC: 36 V to 75 V |
AC: 90 V to 264 V
HVDC: 192 V to 288 V
LVDC: 36 V to 75 V |
AC: 90 V to 264 V
HVDC: 192 V to 288 V
LVDC: 36 V to 75 V |
AC: 176 V to 264 V
DC: 38 V to 75 V |
AC: 90 V to 264 V DC: 36 V to 75 V |
Environment and Reliability |
|
||||
MTBF |
≥ 1,051,000 hours |
≥ 823,000 hours |
≥ 963,000 hours |
≥ 832,000 hours |
≥ 788,000 hours |
Heat dissipation |
Left-to-right and front-to-right airflow |
Front-to-rear airflow |
|||
Operating temperature |
0°C to 45°C (32°F to 115°F) |
||||
Storage temperature |
-40°C to +70°C (-40°F to +158°F) |
||||
Operating humidity |
10% to 90% RH (non-condensing) |
||||
Storage humidity |
5% to 95% RH (non-condensing) |
||||
Operating noise |
45°C: 56.2 dB |
45°C: 57.1 dB |
45°C: 57.9 dB |
27°C: 50 dB 45°C: 65 dB |
27°C: 53 dB 45°C: 68 dB |
Interface surge protection |
Power port: 6 kV/6 kV Telecom port: 10 kV (MGMT port: 4 kV) |
RG-CS85 Series |
|
Feature |
Description |
Ethernet Switching |
Jumbo frame (maximum length: 9216 bytes) |
IEEE 802.1Q (supporting 4K VLANs) |
|
Voice VLAN |
|
Super VLAN, Private VLAN |
|
MAC VLAN, Port based VLAN, Protocol based VLAN, IP-Subnet based VLAN |
|
GVRP |
|
Basic QinQ Flexible QinQ |
|
STP, RSTP, and MSTP |
|
ERPS (G.8032) |
|
LLDP/LLDP-MED |
|
LACP (IEEE 802.3ad) |
|
IP Service |
ARP |
DHCP client, DHCP relay, and DHCP server |
|
DHCP snooping |
|
DNS |
|
DHCPv6 client and DHCPv6 relay |
|
DHCPv6 snooping |
|
Neighbor Discovery (ND) and ND snooping |
|
IP Routing |
Static routing |
RIP and RIPng |
|
OSPFv2, OSPFv3, IS-ISv4, ISv4, and IS-ISv6 |
|
BGP4 and BGP4+ |
|
IPv4 and IPv6 VRF |
|
IPv4 and IPv6 PBR |
|
Multicast |
IGMP v1/v2/v3, and IGMP proxy |
IGMP v1/v2/v3 snooping |
|
PIM-DM, PIM-SM, and PIM-SSM |
|
MSDP |
|
MLD v1/v2 |
|
MLD snooping v1/v2 |
|
PIM-SMv6 and PIM-SSM v6 |
|
MPLS |
MPLS L3VPN |
ACL and QoS |
Standard IP ACLs Extended IP ACLs Extended MAC ACLs Time-based ACLs Expert-level ACLs ACL80 IPv6 ACL |
ACL redirection |
|
Port traffic rate limiting |
|
Congestion management: RR, SP, WRR, DRR, WFQ, SP+WRR, SP+DRR, and SP+WFQ |
|
Congestion avoidance: tail drop, RED, and WRED |
|
802.1p/DSCP/ToS traffic classification Eight priority queues per port |
|
Security |
Multiple AAA modes |
RADIUS and TACAS+ |
|
Port-based and MAC-based 802.1x authentication |
|
Web authentication |
|
HTTPS |
|
SSHv1, SSHv2 |
|
Global IP-MAC binding |
|
Port isolation and port security |
|
IP source guard |
|
SAVI |
|
CPP and NFPP |
|
Strict and loose RPF uRPF ignoring default routes |
|
Reliability |
REUP, RLDP, DLDP |
IPv4 VRRP v2/v3 and IPv6 VRRP |
|
BFD |
|
Link tracing, fault notification, and remote loopback based on 802.3ah (EFM) |
|
Hot swapping of power modules and cables |
|
3-level fan speed adjustment Fan fault alarm |
|
Device virtualization |
Virtual Switching Unit (VSU) |
NMS and maintenance |
SPAN, RSPAN, and ERSPAN |
sFLOW |
|
NTP and SNTP |
|
FTP and TFTP |
|
SNMP v1/v2/v3 |
|
RMON (1, 2, 3, 9) |
|
NETCONF |
|
CWMP (TR-069) standard protocol |
|
gRPC |
|
Cloud and SON |
|
PoE |
IEEE 802.3af and 802.3at Uninterruptible power supply upon hot start Port priority |
Follow the steps to order the RG-CS85 series switches.
"*" in ordering information indicates products supported in the future.
Order switches, expansion modules, power supply modules, and other components as needed. Before ordering an expansion module or power supply module, please contact our online customer service team for the latest support information about the module.
Model |
Description |
RG-CS85-24GT8XS-D |
24 x 10/100/1000 Mbps electrical ports with auto-negotiation, 8 x 1GE/10GE SFP+ ports, 1 x expansion slot, 2 x built-in fixed fans, 2 x power supply module slots (Purchase at least one RG-PA150IB-F module.) |
RG-CS85-48GT4XS-D |
48 x 10/100/1000 Mbps electrical ports with auto-negotiation, 4 x 1GE/10GE SFP+ ports, 1 x expansion slot, 2 x built-in fixed fans, 2 x power supply module slots (Purchase at least one RG-PA150IB-F module.) |
RG-CS85-48GT4XS-HPD |
48 x 10/100/1000 Mbps electrical ports with auto-negotiation, 4 x 1GE/10GE SFP+ ports, 1 x expansion slot, 2 x modular fans, 2 x power supply module slots (Purchase at least one RG-PA600I-P-F/RG-PA1000I-P-F module.) |
RG-CS85-24SFP/8GT8XS-D |
24 x 10/100/1000 Mbps SFP ports (Ports 1-16 are 100/1000 Mbps SFP ports), 8 x 10/100/1000 Mbps combo ports with auto-negotiation, 8 x 1GE/10GE SFP+ ports, 1 x expansion slot, 2 x built-in fans, 2 x power supply module slots (Purchase at least one RG-PA150IB-F module.) |
RG-CS85-48SFP4XS-D |
48 x 1000 Mbps SFP ports, 4 x 1GE/10GE SFP+ ports, 1 x expansion slot, 3 x modular fans, 2 x power supply module slots (Purchase at least one RG-PA150IB-F module.) |
CM85-4XS2CQ |
4 x 10GE SFP+ ports and 2 x 100GE QSFP28 ports |
RG-PA150IB-F |
150 W AC power supply module |
RG-PA600I-P-F |
600 W PoE AC power supply module |
RG-PA1000I-P-F |
1000 W PoE AC power supply module |
Mini-GBIC-GT |
1000BASE-GT mini GBIC module |
MINI-GBIC-SX-MM850 |
Single-port 1000BASE-SX mini GBIC module (LC interface) |
MINI-GBIC-LX-SM1310 |
Single-port 1000BASE-LX mini GBIC module (LC interface) |
MINI-GBIC-LH40-SM1310 |
Single-port 1000BASE-LH mini GBIC module (LC interface), supporting a transmission distance of 40 km (24.85 miles) |
MINI-GBIC-ZX50-SM1550 |
Single-port 1000BASE-ZX mini GBIC module (LC interface), supporting a transmission distance of 50 km (24.85 miles) |
MINI-GBIC-ZX80-SM1550 |
Single-port 1000BASE-ZX mini GBIC module (LC interface), supporting a transmission distance of 80 km (24.85 miles) |
MINI-GBIC-ZX100-SM1550 |
1000BASE-ZX mini GBIC module, supporting a transmission distance of 100 km (62.14 miles) |
XG-SFP-SR-MM850 |
10GE LC module (62.5/125μm: 33 m (108.27 ft); 50/125μm: 66 m (216.54 ft); transmit for 300 m (984.25 ft) when modal bandwidth is 2000Mhz *km), applicable to SFP+ ports |
XG-SFP-LR-SM1310 |
10GE LC interface module (1310 nm), 10 km (6.21 miles), applicable to SFP+ ports |
XG-SFP-ER-SM1550 |
10GE LC interface module (1550 nm), 40 km (24.85 miles), applicable to SFP+ ports |
XG-SFP-AOC1M |
10GE SFP+ fiber-optic cable, 1 m (3.28 ft), including one cable and two interface modules |
XG-SFP-AOC3M |
10GE SFP+ fiber-optic cable, 3 m (3.28 ft), including one cable and two interface modules |
XG-SFP-AOC5M |
10GE SFP+ fiber-optic cable, 5 m (3.28 ft), including one cable and two interface modules |
Ruijie Networks websites use cookies to deliver and improve the website experience.
See our cookie policy for further details on how we use cookies and how to change your cookie settings.
Cookie Manager
When you visit any website, the website will store or retrieve the information on your browser. This process is mostly in the form of cookies. Such information may involve your personal information, preferences or equipment, and is mainly used to enable the website to provide services in accordance with your expectations. Such information usually does not directly identify your personal information, but it can provide you with a more personalized network experience. We fully respect your privacy, so you can choose not to allow certain types of cookies. You only need to click on the names of different cookie categories to learn more and change the default settings. However, blocking certain types of cookies may affect your website experience and the services we can provide you.
Through this type of cookie, we can count website visits and traffic sources in order to evaluate and improve the performance of our website. This type of cookie can also help us understand the popularity of the page and the activity of visitors on the site. All information collected by such cookies will be aggregated to ensure the anonymity of the information. If you do not allow such cookies, we will have no way of knowing when you visited our website, and we will not be able to monitor website performance.
This type of cookie is necessary for the normal operation of the website and cannot be turned off in our system. Usually, they are only set for the actions you do, which are equivalent to service requests, such as setting your privacy preferences, logging in, or filling out forms. You can set your browser to block or remind you of such cookies, but certain functions of the website will not be available. Such cookies do not store any personally identifiable information.
Liên hệ
How can we help you?
Your opinions and feelings are crucial for our improvement.
Fill in the survey